IDF – Transformer Protection Relay IEC 61850 2

Protection relay for two or three winding transformer or autotransformer, of any voltage level, with single or double circuit breaker. IEC 61850 Certificate ed 2

Suitable for phase-shifting transformers, Scott or Leblanc transformers.

Can be applied as a differential protection for reactances, SVCs, generators and motors.

A fast differential unit, complemented by advanced blocking and harmonic restraint logics and an external fault detector, provides great reliability in all types of conditions.

Key Features

  • Differential Units: Includes one unit with percentage restraint and harmonic restraint/blocking, and another unrestrained. The latter allows to accelerate tripping of internal faults with high fault currents that cause CT saturation. Both differential units have up to four three-phase current inputs, allowing protection of windings transformers in breaker-and-a-half or ring-bus schemes.
  • Harmonic Restraint / Blocking: The harmonic restraint and blocking units avoid trips under transformer inrush and overexcitation conditions. The wide variety of cross-blocking logics provide great security during transformer energization with low second harmonic percentage, common in new power transformer designs. Additionally, the dynamic harmonic blocking / restraint logic allows accelerating internal fault trips with CT saturation. Thanks to this last logic and the use of fast outputs, the differential unit trips in subcycle times.
  • External Fault Detector: Blocks the differential unit against external faults with very high CT saturation, providing exceptional security.
  • Restricted Earth Faults: The restricted earth faults unit detects ground faults in one of the windings of the machine, located very close to the neutral point. In addition to the neutral differential unit, the restricted earth faults unit includes a directional comparison unit that increases its security against external faults with CT saturation. The IED has low and high impedance Restricted Earth Faults units.
  • Backup Units: The IDF has up to nine overcurrent units of each type (phase, neutral, negative sequence, ground). Each of them can be configured as a directional unit.

General characteristics of the “ZIV e-NET flex family”:

  • Powerful programable logic
  • 2000 event log. Up to 100 oscillography seconds
  • Alphanumeric or graphic display.
  • 144 ED, 63 SD y 22 LEDs.
  • IEC 61850 ed. 1 & ed. 2 protocols, DNP3.0, Modbus RTU and PROCOME
  • Bonding, RSTP, PRP and HSR redundancy
  • Native process bus. Analog input cards operate as Merging Units for the CPU. Synchronized samples at 4800 Hz (as per IEC 61869-9)
  • Cybersecurity in accordance with IEC 62351 and IEEE 1686-2013 standards. RBAC, secure keys, physical and logical port disabling, cybersecurity event log, and securing of management protocols (PROCOME, HTTPS, SFTP, SSH)
  • Time synchronization by IRIG-B, SNTP and PTP (Ordinary Clock / Transparent Clock